{"id":15504,"date":"2026-07-29T07:07:07","date_gmt":"2026-07-29T07:07:07","guid":{"rendered":"https:\/\/www.zhengxi1983.com\/?p=15504"},"modified":"2026-07-29T07:07:08","modified_gmt":"2026-07-29T07:07:08","slug":"voltage-stabilizer-trips-when-motor-starts","status":"publish","type":"post","link":"https:\/\/www.zhengxi1983.com\/nl\/voltage-stabilizer-trips-when-motor-starts\/","title":{"rendered":"Waarom slaat een spanningsstabilisator af wanneer een motor of compressor start?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Heeft u ooit een spanningsstabilisator ge\u00efnstalleerd, om vervolgens te ontdekken dat deze&nbsp;<strong>schakelt onmiddellijk uit zodra een luchtcompressor, waterpomp, koelcompressor of industri\u00eble motor wordt gestart<\/strong>? Hoewel de stabilisator bij normale belasting perfect functioneert, schakelt deze plotseling uit zodra de motor begint te draaien.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dit is een van de meest gestelde vragen door fabriekseigenaren, HVAC-aannemers en installateurs van apparatuur. In de meeste gevallen is de stabilisator niet defect \u2014 hij beschermt zichzelf gewoon tegen een tijdelijke elektrische storing die bekendstaat als&nbsp;<strong>aanloopstroom van de motor<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Als u begrijpt waarom dit gebeurt, kunt u de juiste capaciteit van de stabilisator kiezen, onnodige stilstandtijd voorkomen en de betrouwbaarheid van de apparatuur verbeteren.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>In deze handleiding zullen wij het volgende toelichten:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Waarom motoren tijdens het opstarten een extreem hoge stroomsterkte verbruiken<\/li>\n\n\n\n<li>Waarom spanningsstabilisatoren uitschakelen tijdens het starten van een motor<\/li>\n\n\n\n<li>Hoe spanningsverlies de beveiliging van de stabilisator be\u00efnvloedt<\/li>\n\n\n\n<li>Hoe u de juiste afmetingen van een stabilisator voor compressoren en motoren bepaalt<\/li>\n\n\n\n<li>Praktische oplossingen om ongewenste uitschakelingen te voorkomen<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Wat gebeurt er wanneer een motor start?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In tegenstelling tot resistieve belastingen zoals verwarmingselementen of verlichting, hebben inductiemotoren een zeer grote hoeveelheid stroom nodig om de traagheid te overwinnen en voldoende startkoppel te genereren.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gedurende de eerste paar honderd milliseconden na het opstarten gedraagt de motor zich bijna alsof er kortsluiting is.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Deze tijdelijke piek wordt als volgt genoemd:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Startstroom van de motor<\/li>\n\n\n\n<li>Stroom bij geblokkeerde rotor (LRA)<\/li>\n\n\n\n<li>Inschakelstroom<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Afhankelijk van het ontwerp van de motor kan de aanloopstroom oplopen tot:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>3\u20135\u00d7 de nominale stroom (motoren met zachte aanloop)<\/li>\n\n\n\n<li>5\u20137\u00d7 de nominale stroom (standaard inductiemotoren)<\/li>\n\n\n\n<li>6\u201310\u00d7 de nominale stroom (luchtcompressoren)<\/li>\n\n\n\n<li>8\u201312\u00d7 de nominale stroom (zware industri\u00eble apparatuur)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Hoewel de spanningspiek slechts een fractie van een seconde duurt, is deze groot genoeg om de beveiligingsschakelingen in veel spanningsstabilisatoren te activeren.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Voorbeeld:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><figure class=\"wp-block-table\"><div class=\"scroll\"><table class=\"has-fixed-layout\"><tbody><tr><th>Nominaal vermogen van de motor<\/th><th>Nominale stroom<\/th><th>Startstroom<\/th><\/tr><tr><td>5 pk<\/td><td>8 A<\/td><td>48 A<\/td><\/tr><tr><td>10 PK<\/td><td>16 A<\/td><td>96 A<\/td><\/tr><tr><td>20 pk<\/td><td>32 A<\/td><td>180\u2013220 A<\/td><\/tr><\/tbody><\/table><\/div><\/figure><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u3010img\u3011<br><em>Alternatief: De startstroom van de motor vergeleken met de normale bedrijfsstroom, waarbij de piek van de inschakelstroom zichtbaar is<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Waarom slaat de spanningsstabilisator af?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Moderne automatische spanningsstabilisatoren zijn voorzien van diverse beveiligingsfuncties om zowel de stabilisator als de aangesloten apparatuur te beschermen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wanneer een motor start, kunnen een of meer beveiligingsmechanismen in werking treden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Beveiliging tegen overbelasting<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De meest voorkomende reden is beveiliging tegen overbelasting.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Indien de aanloopstroom van de motor de momentane overbelastingscapaciteit van de stabilisator overschrijdt, schakelt het beveiligingsrelais de uitgang uit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bijvoorbeeld:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nominaal vermogen van de 20 kVA-stabilisator: circa 30 A<\/li>\n\n\n\n<li>Stroombehoefte bij het opstarten van de motor: 150 A<\/li>\n\n\n\n<li>Het beveiligingssysteem detecteert een te hoge stroomsterkte<\/li>\n\n\n\n<li>De uitgang wordt onmiddellijk uitgeschakeld<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">2. Spanningsval aan de ingang<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Een hoge inschakelstroom veroorzaakt een tijdelijke spanningsdaling in het elektriciteitsnet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bijvoorbeeld:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Normale voedingsspanning: 400 V<\/li>\n\n\n\n<li>De motor start<\/li>\n\n\n\n<li>De spanning daalt tot 310 V<\/li>\n\n\n\n<li>De stabilisator detecteert een te lage spanning<\/li>\n\n\n\n<li>De beveiliging wordt geactiveerd<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dit probleem wordt nog ernstiger wanneer:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Hoogspanningsleidingen zijn lang<\/li>\n\n\n\n<li>De kabels hebben een te kleine doorsnede<\/li>\n\n\n\n<li>Generatoren hebben een beperkte capaciteit<\/li>\n\n\n\n<li>De impedantie van de transformator is hoog<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u3010img\u3011<br><em>Alternatief: Een spanningsdaling tijdens het opstarten van de compressor leidt tot het in werking treden van de beveiliging van de spanningsstabilisator<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Vertraging bij het herstel van de uitgangsspanning<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Servospanningsstabilisatoren hebben enige tijd nodig om de uitgangsspanning aan te passen nadat zij een plotselinge verandering in de ingangsspanning hebben gedetecteerd.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Indien de spanning sneller verandert dan de servomotor kan compenseren, kan de beveiliging in werking treden voordat het herstel van de spanning is voltooid.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Interne thermische beveiliging<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Het veelvuldig starten van motoren leidt tot herhaaldelijke overbelastingssituaties.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Na meerdere startbeurten raken de wikkelingen van de transformator en de vermogenscomponenten oververhit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Om schade te voorkomen, wordt de stabilisator tijdelijk uitgeschakeld door de thermische beveiliging.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Waarom compressoren meer problemen veroorzaken dan gewone motoren<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Luchtcompressoren en koelcompressoren behoren tot de meest veeleisende elektrische verbruikers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In tegenstelling tot centrifugaalpompen starten compressoren vaak onder druk, waardoor een aanzienlijk hoger startkoppel vereist is.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dit resulteert in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Hogere stroom bij geblokkeerde rotor<\/li>\n\n\n\n<li>Langere opstarttijd<\/li>\n\n\n\n<li>Grotere spanningsdaling<\/li>\n\n\n\n<li>Hogere mechanische belasting<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Typische opstartstromen van compressoren:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><figure class=\"wp-block-table\"><div class=\"scroll\"><table class=\"has-fixed-layout\"><tbody><tr><th>Uitrusting<\/th><th>Bedrijfsstroom<\/th><th>Startup Current<\/th><\/tr><tr><td>Spiraalcompressor<\/td><td>15 A<\/td><td>80\u2013100 A<\/td><\/tr><tr><td>Schroefcompressor<\/td><td>40 A<\/td><td>200\u2013300 A<\/td><\/tr><tr><td>Zuigercompressor<\/td><td>25 A<\/td><td>150\u2013220 A<\/td><\/tr><\/tbody><\/table><\/div><\/figure><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Dit verklaart waarom veel spanningsstabilisatoren die perfect functioneren bij verlichting of verwarmingsbelastingen, plotseling uitschakelen wanneer ze op compressoren worden aangesloten.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3010img\u3011<br><em>Alternatief: De aanloopstroom van de compressor vergeleken met het nominale vermogen van de servospanningsstabilisator<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Hoe u de juiste capaciteit van een spanningsstabilisator voor motoren bepaalt<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Een van de grootste fouten bij de installatie is het bepalen van de juiste grootte van de stabilisator uitsluitend op basis van het bedrijfsvermogen van de motor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In plaats daarvan zouden ingenieurs het volgende in overweging moeten nemen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Startstroom van de motor<\/li>\n\n\n\n<li>Vermogensfactor<\/li>\n\n\n\n<li>Startprocedure<\/li>\n\n\n\n<li>Activiteitscyclus<\/li>\n\n\n\n<li>Spanningsschommelingen<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Algemene aanbeveling<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><figure class=\"wp-block-table\"><div class=\"scroll\"><table class=\"has-fixed-layout\"><tbody><tr><th>Methode voor het starten van de motor<\/th><th>Aanbevolen grootte van de stabilisator<\/th><\/tr><tr><td>Direct online (DOL)<\/td><td>2,5\u20133 \u00d7 het nominaal vermogen van de motor<\/td><\/tr><tr><td>Ster-Delta<\/td><td>1,8\u20132 \u00d7 het nominale vermogen van de motor<\/td><\/tr><tr><td>Zachte starter<\/td><td>1,3\u20131,5 \u00d7 het nominaal vermogen van de motor<\/td><\/tr><tr><td>Variabele frequentieaandrijving (VFD)<\/td><td>1,2\u20131,3 \u00d7 nominaal vermogen van de motor<\/td><\/tr><\/tbody><\/table><\/div><\/figure><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Voorbeeld:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Voor een compressor van 15 kW kan het volgende nodig zijn:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>15 kVA voor het gebruik<\/li>\n\n\n\n<li>Stabilisator van 40\u201350 kVA bij DOL-start<\/li>\n\n\n\n<li>25\u201330 kVA met softstarter<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Praktische manieren om te voorkomen dat spanningsstabilisatoren uitschakelen<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Kies een grotere stabilisator<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Door de capaciteit van de stabilisator te vergroten, ontstaat er een grotere overbelastingsmarge tijdens het opstarten.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Gebruik een zachte starter<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Softstarters verhogen de motorspanning geleidelijk, waardoor de inschakelstroom aanzienlijk wordt verminderd.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Typische reductie:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>600%-startstroom \u2192 250\u2013300%<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Installeer een frequentieregelaar (VFD)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Een VFD regelt de versnelling elektronisch en kan de aanloopstroom tot dicht bij de nominale stroom verlagen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Naast het voorkomen van uitschakelingen van de stabilisator zorgen frequentieregelaars ook voor een verbetering van de energie-effici\u00ebntie en de levensduur van de motor.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">De kabeldoorsnede verbeteren<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Te dunne kabels zorgen voor een grotere spanningsval.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Door de juiste kabeldoorsnede te kiezen, wordt de daling van de ingangsspanning tijdens het opstarten van de motor tot een minimum beperkt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Controleer de capaciteit van de generator<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Indien de stabilisator wordt gevoed door een dieselgenerator, dient u ervoor te zorgen dat de generator de inschakelstroom van de motor kan opvangen zonder dat er een overmatige spanningsdaling optreedt.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Servostabilisator versus statische stabilisator voor motorbelastingen<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><figure class=\"wp-block-table\"><div class=\"scroll\"><table class=\"has-fixed-layout\"><tbody><tr><th>Functie<\/th><th>Servostabilisator<\/th><th>Statische stabilisator<\/th><\/tr><tr><td>Reactiesnelheid<\/td><td>Medium<\/td><td>Zeer snel<\/td><\/tr><tr><td>Startprestaties van de motor<\/td><td>Goed<\/td><td>Uitstekend<\/td><\/tr><tr><td>Spanningscorrectie<\/td><td>Mechanisch<\/td><td>Elektronisch<\/td><\/tr><tr><td>Frequente belastingswisselingen<\/td><td>Matig<\/td><td>Uitstekend<\/td><\/tr><tr><td>Industri\u00eble compressoren<\/td><td>Geschikt<\/td><td>Een echte aanrader<\/td><\/tr><\/tbody><\/table><\/div><\/figure><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Installaties waarbij de compressor vaak in- en uitschakelt, hebben vaak baat bij statische spanningsstabilisatoren vanwege hun reactiesnelheid op millisecondeniveau.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3010img\u3011<br><em>Alternatief: Vergelijking tussen een servospanningsstabilisator en een statische spanningsstabilisator bij het opstarten van een motor<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Branchenormen en technische referenties<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Het startgedrag van motoren en de spanningskwaliteit zijn uitgebreid gedocumenteerd door internationale organisaties.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>IEEE-norm 3004 \u2013 Technische werkwijzen voor motorsystemen<\/li>\n\n\n\n<li>IEC 60034 \u2013 Draaiende elektrische machines<\/li>\n\n\n\n<li>IEC 61000 \u2013 Elektromagnetische compatibiliteit en spanningskwaliteit<\/li>\n\n\n\n<li>Technische handleiding van ABB \u2013 Methoden voor het starten van motoren<\/li>\n\n\n\n<li>Schneider Electric \u2013 Motorbeveiliging en stroomkwaliteit<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Uit deze bronnen blijkt dat een hoge inschakelstroom en tijdelijke spanningsdalingen normale elektrische verschijnselen zijn waarmee bij het ontwerp van het systeem rekening moet worden gehouden.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<div class=\"schema-faq wp-block-yoast-faq-block\"><div class=\"schema-faq-section\" id=\"faq-question-1785308781385\"><strong class=\"schema-faq-question\">Kan een kleine stabilisator een motor beschadigen?<\/strong> <p class=\"schema-faq-answer\">Ja. Indien de stabilisator tijdens het opstarten herhaaldelijk uitschakelt, kan dit bij de motor leiden tot onvolledige startpogingen, oververhitting en verhoogde mechanische belasting.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1785308791887\"><strong class=\"schema-faq-question\">Zal een softstarter het uitschakelen van de stabilisator voorkomen?<\/strong> <p class=\"schema-faq-answer\">In veel toepassingen is dat inderdaad het geval. Softstarters zorgen voor een aanzienlijke vermindering van de aanloopstroom en de spanningsdaling, waardoor de kans dat de overbelastingsbeveiliging in werking treedt, afneemt.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1785308808324\"><strong class=\"schema-faq-question\">Moet ik de stabilisator afstemmen op het motorvermogen in pk?<\/strong> <p class=\"schema-faq-answer\">Nee. Houd altijd rekening met de aanloopstroom, de vermogensfactor, de belastingskenmerken en de aanloopmethode, in plaats van uitsluitend af te gaan op het motorvermogen in pk.<\/p> <\/div> <\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusie<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Een spanningsstabilisator schakelt meestal uit tijdens het opstarten van een motor of compressor, omdat de apparatuur een zeer hoge&nbsp;<strong>inschakelstroom<\/strong>, wat leidt tot een overbelasting of een tijdelijke&nbsp;<strong>spanningsdaling<\/strong>. In de meeste gevallen functioneert de stabilisator precies zoals bedoeld, door zichzelf en de aangesloten belasting te beschermen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tot de meest effectieve oplossingen behoren het kiezen van de juiste capaciteit van de stabilisator, het verminderen van de aanloopstroom met behulp van een softstarter of een frequentieregelaar, het verbeteren van de stroomverdeling en het waarborgen dat de stroombron bestand is tegen tijdelijke piekbelastingen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Indien uw toepassing gebruikmaakt van luchtcompressoren, koelsystemen, pompen, CNC-machines of andere zware motorbelastingen, is het voor een betrouwbare werking op lange termijn van essentieel belang dat u kiest voor een stabilisator die specifiek is ontworpen voor hoge inschakelstroom.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Heeft u hulp nodig bij het kiezen van de juiste spanningsstabilisator voor apparatuur met een motor?<\/strong><br>ZHENGXI is gespecialiseerd in industri\u00eble servo- en statische spanningsstabilisatoren die zijn ontworpen voor compressoren, pompen, HVAC-systemen en productieapparatuur. Neem contact op met ons technisch team voor een op maat gemaakt advies over de juiste dimensionering, op basis van het vermogen van uw motor, de startmethode en de omstandigheden ter plaatse.<\/p>","protected":false},"excerpt":{"rendered":"<p>Have you ever installed a voltage stabilizer only to find that it&nbsp;trips immediately when an air compressor, water pump, refrigeration compressor, or industrial motor starts? While the stabilizer works perfectly under normal loads, it suddenly shuts down the moment the motor begins rotating. This is one of the most common questions asked by factory owners, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[36],"tags":[],"class_list":["post-15504","post","type-post","status-publish","format-standard","hentry","category-product-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Why Does a Voltage Stabilizer Trip When a Motor Starts? | AVR Manufacturer - ZHENGXI<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.zhengxi1983.com\/nl\/voltage-stabilizer-trips-when-motor-starts\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why Does a Voltage Stabilizer Trip When a Motor Starts? | AVR Manufacturer - ZHENGXI\" \/>\n<meta property=\"og:description\" content=\"Have you ever installed a voltage stabilizer only to find that it&nbsp;trips immediately when an air compressor, water pump, refrigeration compressor, or industrial motor starts? While the stabilizer works perfectly under normal loads, it suddenly shuts down the moment the motor begins rotating. This is one of the most common questions asked by factory owners, [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.zhengxi1983.com\/nl\/voltage-stabilizer-trips-when-motor-starts\/\" \/>\n<meta property=\"og:site_name\" content=\"ZHENGXI\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ZXstabilizer\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-29T07:07:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-29T07:07:08+00:00\" \/>\n<meta name=\"author\" content=\"zhengxi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@juanzen5\" \/>\n<meta name=\"twitter:site\" content=\"@juanzen5\" \/>\n<meta name=\"twitter:label1\" content=\"Geschreven door\" \/>\n\t<meta name=\"twitter:data1\" content=\"zhengxi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Verwachte leestijd\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/\"},\"author\":{\"name\":\"zhengxi\",\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/#\\\/schema\\\/person\\\/78921289cf7d104be699851ab5ef5b63\"},\"headline\":\"Why Does a Voltage Stabilizer Trip When a Motor or Compressor Starts?\",\"datePublished\":\"2026-07-29T07:07:07+00:00\",\"dateModified\":\"2026-07-29T07:07:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/\"},\"wordCount\":1188,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/#organization\"},\"articleSection\":[\"Industry Blog\"],\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#respond\"]}]},{\"@type\":[\"WebPage\",\"FAQPage\"],\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/\",\"url\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/\",\"name\":\"Why Does a Voltage Stabilizer Trip When a Motor Starts? | AVR Manufacturer - ZHENGXI\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/#website\"},\"datePublished\":\"2026-07-29T07:07:07+00:00\",\"dateModified\":\"2026-07-29T07:07:08+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#breadcrumb\"},\"mainEntity\":[{\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#faq-question-1785308781385\"},{\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#faq-question-1785308791887\"},{\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#faq-question-1785308808324\"}],\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.zhengxi1983.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industry Blog\",\"item\":\"https:\\\/\\\/www.zhengxi1983.com\\\/category\\\/product-blog\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Why Does a Voltage Stabilizer Trip When a Motor or Compressor Starts?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/#website\",\"url\":\"https:\\\/\\\/www.zhengxi1983.com\\\/\",\"name\":\"ZHENGXI\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.zhengxi1983.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/#organization\",\"name\":\"ZHENGXI\",\"url\":\"https:\\\/\\\/www.zhengxi1983.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.zhengxi1983.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/zhengxi-logo.webp\",\"contentUrl\":\"https:\\\/\\\/www.zhengxi1983.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/zhengxi-logo.webp\",\"width\":245,\"height\":50,\"caption\":\"ZHENGXI\"},\"image\":{\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/ZXstabilizer\",\"https:\\\/\\\/x.com\\\/juanzen5\",\"https:\\\/\\\/www.youtube.com\\\/@zx-ele\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/107531565\\\/admin\\\/dashboard\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/#\\\/schema\\\/person\\\/78921289cf7d104be699851ab5ef5b63\",\"name\":\"zhengxi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=mm&r=g\",\"caption\":\"zhengxi\"},\"sameAs\":[\"https:\\\/\\\/www.zhengxi1983.com\\\/\"]},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#faq-question-1785308781385\",\"position\":1,\"url\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#faq-question-1785308781385\",\"name\":\"Can a small stabilizer damage a motor?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. If the stabilizer repeatedly trips during startup, the motor may experience incomplete starts, overheating, and increased mechanical stress.\",\"inLanguage\":\"nl-NL\"},\"inLanguage\":\"nl-NL\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#faq-question-1785308791887\",\"position\":2,\"url\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#faq-question-1785308791887\",\"name\":\"Will a soft starter eliminate stabilizer trips?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"In many applications, yes. Soft starters significantly reduce startup current and voltage dip, lowering the chance of overload protection activation.\",\"inLanguage\":\"nl-NL\"},\"inLanguage\":\"nl-NL\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#faq-question-1785308808324\",\"position\":3,\"url\":\"https:\\\/\\\/www.zhengxi1983.com\\\/voltage-stabilizer-trips-when-motor-starts\\\/#faq-question-1785308808324\",\"name\":\"Should I size the stabilizer based on motor horsepower?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Always consider starting current, power factor, load characteristics, and startup method rather than relying solely on motor horsepower.\",\"inLanguage\":\"nl-NL\"},\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Waarom slaat een spanningsstabilisator af wanneer een motor start? | AVR-fabrikant - ZHENGXI","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.zhengxi1983.com\/nl\/voltage-stabilizer-trips-when-motor-starts\/","og_locale":"nl_NL","og_type":"article","og_title":"Why Does a Voltage Stabilizer Trip When a Motor Starts? | AVR Manufacturer - ZHENGXI","og_description":"Have you ever installed a voltage stabilizer only to find that it&nbsp;trips immediately when an air compressor, water pump, refrigeration compressor, or industrial motor starts? While the stabilizer works perfectly under normal loads, it suddenly shuts down the moment the motor begins rotating. This is one of the most common questions asked by factory owners, [&hellip;]","og_url":"https:\/\/www.zhengxi1983.com\/nl\/voltage-stabilizer-trips-when-motor-starts\/","og_site_name":"ZHENGXI","article_publisher":"https:\/\/www.facebook.com\/ZXstabilizer","article_published_time":"2026-07-29T07:07:07+00:00","article_modified_time":"2026-07-29T07:07:08+00:00","author":"zhengxi","twitter_card":"summary_large_image","twitter_creator":"@juanzen5","twitter_site":"@juanzen5","twitter_misc":{"Geschreven door":"zhengxi","Verwachte leestijd":"6 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#article","isPartOf":{"@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/"},"author":{"name":"zhengxi","@id":"https:\/\/www.zhengxi1983.com\/#\/schema\/person\/78921289cf7d104be699851ab5ef5b63"},"headline":"Why Does a Voltage Stabilizer Trip When a Motor or Compressor Starts?","datePublished":"2026-07-29T07:07:07+00:00","dateModified":"2026-07-29T07:07:08+00:00","mainEntityOfPage":{"@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/"},"wordCount":1188,"commentCount":0,"publisher":{"@id":"https:\/\/www.zhengxi1983.com\/#organization"},"articleSection":["Industry Blog"],"inLanguage":"nl-NL","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#respond"]}]},{"@type":["WebPage","FAQPage"],"@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/","url":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/","name":"Waarom slaat een spanningsstabilisator af wanneer een motor start? | AVR-fabrikant - ZHENGXI","isPartOf":{"@id":"https:\/\/www.zhengxi1983.com\/#website"},"datePublished":"2026-07-29T07:07:07+00:00","dateModified":"2026-07-29T07:07:08+00:00","breadcrumb":{"@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#breadcrumb"},"mainEntity":[{"@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#faq-question-1785308781385"},{"@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#faq-question-1785308791887"},{"@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#faq-question-1785308808324"}],"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.zhengxi1983.com\/"},{"@type":"ListItem","position":2,"name":"Industry Blog","item":"https:\/\/www.zhengxi1983.com\/category\/product-blog\/"},{"@type":"ListItem","position":3,"name":"Why Does a Voltage Stabilizer Trip When a Motor or Compressor Starts?"}]},{"@type":"WebSite","@id":"https:\/\/www.zhengxi1983.com\/#website","url":"https:\/\/www.zhengxi1983.com\/","name":"ZHENGXI","description":"","publisher":{"@id":"https:\/\/www.zhengxi1983.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.zhengxi1983.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/www.zhengxi1983.com\/#organization","name":"ZHENGXI","url":"https:\/\/www.zhengxi1983.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/www.zhengxi1983.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.zhengxi1983.com\/wp-content\/uploads\/2025\/08\/zhengxi-logo.webp","contentUrl":"https:\/\/www.zhengxi1983.com\/wp-content\/uploads\/2025\/08\/zhengxi-logo.webp","width":245,"height":50,"caption":"ZHENGXI"},"image":{"@id":"https:\/\/www.zhengxi1983.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ZXstabilizer","https:\/\/x.com\/juanzen5","https:\/\/www.youtube.com\/@zx-ele","https:\/\/www.linkedin.com\/company\/107531565\/admin\/dashboard\/"]},{"@type":"Person","@id":"https:\/\/www.zhengxi1983.com\/#\/schema\/person\/78921289cf7d104be699851ab5ef5b63","name":"zhengxi","image":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=mm&r=g","caption":"zhengxi"},"sameAs":["https:\/\/www.zhengxi1983.com\/"]},{"@type":"Question","@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#faq-question-1785308781385","position":1,"url":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#faq-question-1785308781385","name":"Kan een kleine stabilisator een motor beschadigen?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"Yes. If the stabilizer repeatedly trips during startup, the motor may experience incomplete starts, overheating, and increased mechanical stress.","inLanguage":"nl-NL"},"inLanguage":"nl-NL"},{"@type":"Question","@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#faq-question-1785308791887","position":2,"url":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#faq-question-1785308791887","name":"Zal een softstarter het uitschakelen van de stabilisator voorkomen?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"In many applications, yes. Soft starters significantly reduce startup current and voltage dip, lowering the chance of overload protection activation.","inLanguage":"nl-NL"},"inLanguage":"nl-NL"},{"@type":"Question","@id":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#faq-question-1785308808324","position":3,"url":"https:\/\/www.zhengxi1983.com\/voltage-stabilizer-trips-when-motor-starts\/#faq-question-1785308808324","name":"Moet ik de stabilisator afstemmen op het motorvermogen in pk?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"No. Always consider starting current, power factor, load characteristics, and startup method rather than relying solely on motor horsepower.","inLanguage":"nl-NL"},"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/www.zhengxi1983.com\/nl\/wp-json\/wp\/v2\/posts\/15504","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zhengxi1983.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.zhengxi1983.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.zhengxi1983.com\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.zhengxi1983.com\/nl\/wp-json\/wp\/v2\/comments?post=15504"}],"version-history":[{"count":2,"href":"https:\/\/www.zhengxi1983.com\/nl\/wp-json\/wp\/v2\/posts\/15504\/revisions"}],"predecessor-version":[{"id":15507,"href":"https:\/\/www.zhengxi1983.com\/nl\/wp-json\/wp\/v2\/posts\/15504\/revisions\/15507"}],"wp:attachment":[{"href":"https:\/\/www.zhengxi1983.com\/nl\/wp-json\/wp\/v2\/media?parent=15504"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.zhengxi1983.com\/nl\/wp-json\/wp\/v2\/categories?post=15504"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.zhengxi1983.com\/nl\/wp-json\/wp\/v2\/tags?post=15504"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}