Key Features
- No Mechanical Parts: Operates without carbon brushes or moving parts, which creates durability and low maintenance.
Fast Voltage Stabilization: It corrects the voltage fluctuations right away to maintain consistent output.
Automatic Three-Phase Balance: The three-phase voltages are automatically adjusted so the output voltage of all phases is consistent.
Customizable Design: It can be designed with various needs for voltage standards and capacity.
Surge Protection: Protects against high-current surges up to 40KA.
EMI Filtering: Ensures cleaner power supply through the reduction of electromagnetic interference.
High efficiency due to contactless operation reduces energy losses.
Protection against overvoltage, undervoltage, and other electrical disturbances.
Technical Specification
| Input Voltage | Regulators scope | Three Phase304V-456V,One Phase176V-264V |
| Frequency | 50HZ/60HZ | |
| Output Voltage | Rated voltage | Phase Voltage 220V,Line Voltage 380V |
| Regulators accuracy | ±(1-5)% option(±2.5%for the conventional) | |
| Response time | ≤10ms | |
| Waveform distortion | Do not produce additional waveform distortion(static) | |
| Efficiency | ≥98% | |
| Three-phase | Automatic three-phase voltage balance | |
| imbalance | ||
| Delay output | Again from the first regulator(protective equipment without shocks) | |
| Overvoltage | The output voltage of more than 10%(245V),or cut output to bypass uninterrupted | |
| Under voltage | The output voltage of less than 10%(195V),or cut output to bypass uninterrupted | |
| Protection | Lack of phase | automatically cut |
| Overload | Electronic detection, within three minutes overload cut output | |
| Short circuit | Dual electronic detection and protection circut breakers | |
| Over current | Dual electronic detection and protection circut breakers | |
| Bypass | Manual or automatic bypass uninterrupted | |
| Lights | Voltage | A,B,C,respectively, with three-phase ABC TRMS figures show |
| Current | A,B,C,respectively, with three-phase ABC TRMS figures show | |
| Working conditions | Regulators stae/bypass state | |
| Abnormal | Over-voltage, under-voltage, overload, fuse fault | |
| Work methods | The two regulators are working methods and bypass | |
| Overload | Five times the rated current 1 seconds | |
Applications
CNC Machining Centers: Keeps the voltage steady so your high-performance machines run smoothly.
Medical Equipment: Delivers clean and stable power for sensitive devices that need to operate reliably.
Printing Machinery: Shields against voltage fluctuations to avoid interruptions and potential damage.
Environmental Testing Equipment: Provides dependable power, even when conditions change.
Electronic Testing and Communication Equipment: Ensures uninterrupted operation in environments with significant power grid disturbances or voltage fluctuations.
Large-Scale Power Grids: Works great in spots where the power grid has big fluctuations, spikes, or drops.
ZBW series of electronic and mechanical SBW series differs from the exch ange regulator comparison
| Specifications | SBW series of high-power automatic compensation | ZBW series microcomputer compensation of non-contact |
| principle | Carbon Brush-rely on the surge in themobile transformer change compensation voltage transformer secondary winding maintain out-put voltage stability. There Carbon Brush, contacts, mechanical transmission. | By microprocessors and large-scale logiccircuits (PLD)ex-change control in the AC voltage is switched off 0.1 of a combination of transformer switching compensation main output voltage stability. No Carbon Brush, No contact, no machinery, the three-phase transfer. |
| Response time | Slower(about 200 ms) | Express(<10ms) |
| Voltage adjustment rate | Slow(20V/S,V per second adjustment20V ) | Express(20%jump voltage, voltage stability to the center)of time<10ms) |
| Three-phase | EC does not have three-phase voltage-automatic balance function | Automatic three-phase voltage balance, the three-phase transfer |
| imbalance of | ||
| Starting ease | Non-conventional products | A functional again from the first regulator |
| impact | ||
| Automatically boot | Non-conventional products | No, one bailiffs have Shou function automatically boot |
| Anti-harmonic | There is no such function | Voltage, current acquisition have anti-harmonic function, load equipment in the power grid or serious harmonic interference, the output voltage can still, maitain stability, current measurement can still maintain accurate |
| function | ||
| Fault Protection | Cut Output | Protection time soon, cutting output or uninterrupted automatically converted to bypass work |
| Bypass function | The manual bypass | There are (and can automatically bypass uninterruped) |
| Periodic | Regular maintenance | Maintenance-free |
| maintenance | ||
| Parameters | Pointer | Various parameters TRMS figures show |
| Parameter settings | Simulation potentiometer adjustments, or may not ses | Digital touch key setting |