Why Choose ZHENGXI 3 Phase Smart UPS?
✔ Advanced DSP Digital Control
Equipped with full-digital DSP control, the system delivers:
- Higher response speed
- Enhanced stability
- Improved reliability under fluctuating grid conditions
- Better accuracy in voltage and frequency regulation
This ensures your equipment stays protected even in demanding power environments.
Zero-Interruption Online Double-Conversion Technology
The Online UPS offers:
- True 0 ms switching time
- Continuous VFI (Voltage-Frequency Independent) output
- Protection against surges, harmonics, brownouts, phase imbalance, and power interruptions
This makes it ideal for highly sensitive and mission-critical equipment.
Smart UPS Technology for Efficiency & Flexibility
High input power factor ≥0.99 for reduced grid pollution
High efficiency up to 92% lowering operational costs
Wide input voltage and frequency range, perfect for unstable grids and generator use
Automatic frequency adaptation (50/60Hz)
Selectable output modes for various load types
The UPS intelligently adjusts to real-world loads, offering stable power under both linear and nonlinear conditions.
Scalable Monitoring & Communication Options
The system includes a multifunction Smart Slot compatible with:
- USB communication
- SNMP network card
- RS485 port
- AS400 card
- Environmental monitoring module
This makes the UPS suitable for modern data center environments requiring real-time monitoring.
Environmentally Friendly & Energy Efficient
Designed with green power components:
- Reduced switching losses
- Lower harmonic pollution
- Eco-friendly materials that comply with national electronic pollution control standards
Key Features
Ultra-Wide Input Voltage Range
Perfect for regions with unstable power supply:
- Reduces battery cycling
- Extends battery service life
- Ensures stable output even during severe fluctuations
High Overload Tolerance
- 105–125% load → 1 min
- 125–135% load → 30 sec
- 135% load → 300 ms before transfer to bypass
Ensures your power system never abruptly shuts down.
Low Harmonic Distortion
Output THD ≤3%, providing pure and stable sine wave output for sensitive electronics.
Generator-Compatible
The UPS effectively filters generator output, protecting loads from noise, spikes, and unstable frequency.
Technical Specifications
| Item | GW31-10KVA | GW31-15KVA | GW31-20KVA |
| Rated power | 10KVA/9KW | 15KVA/13.5KW | 20KVA/18KW |
| Voltage range | 207~475Vac three-phase four wire + grounding wire | ||
| Operating frequency range | 40-70Hz (adjustable) | ||
| Input power factor | ≥0.99 | ||
| Rated voltage & accuracy | 220Vac (±1%) single-phase two wire + grounding wire | ||
| Frequency | 46-54Hz mains; 50Hz battery | ||
| Rated current | 45A | 68A | 91A |
| Output power factor | 0.9 | ||
| Output harmonic | ≤3% | ||
| Crest factor | 3:1 | ||
| Over load | 105–125%: 1 min to bypass; 125–135%: 30s to bypass; >135%: 300s to bypass | ||
| Conversion time (mains→battery) | 0ms | ||
| Efficiency | 92% | ||
| Rated voltage (battery) | 192Vdc | ||
| Battery sections | 1/16/1900 | ||
| Charging current | 5.5A | ||
| Machine size (mm) | 533×260×501 | ||
| Machine weight | 23kg | 32kg | 33kg |
| Ambient temperature | 0°C~40°C | ||
| Working relative humidity | 20%~95% | ||
| Noise | ≤60dB | ||
Applications
Suitable for industries requiring stable, uninterrupted 3-phase power:
- Data centers & server rooms
- Precision manufacturing
- Metro, airport & transportation hubs
- Financial institutions
- Medical imaging & hospital equipment
- Telecom & network operations
- Industrial control systems
- Security systems & broadcasting stations
Benefits at a Glance
- Continuous clean power
- High efficiency, low operating cost
- Supports complex & nonlinear loads
- Wide adaptability to harsh grid environments
- Long service life with minimal maintenance
- Supports extended battery banks
FAQ
1. Is a 3-phase UPS necessary for industrial equipment?
Yes. A 3-phase UPS is ideal for high-power equipment such as motors, CNC machines, pumps, elevators, servers, and medical instruments. It provides balanced output, higher efficiency, and stronger overload capability compared to single-phase UPS systems.
2. What is the difference between online UPS and offline UPS?
| Online UPS | Offline UPS |
|---|---|
| Zero transfer time | Has a small transfer delay |
| Double-conversion clean power | Only activates when mains fails |
| Ideal for sensitive equipment | Suitable for basic home/office loads |
| Higher cost, higher protection | Lower cost, lower protection |
For industrial and IT applications, online UPS is strongly recommended.
3. How do I choose between 10kVA, 15kVA, and 20kVA UPS?
Base your choice on:
-
Total load power
-
Starting surge current
-
Whether loads are nonlinear (motors, compressors, servers)
-
Expansion needs in the next 3–5 years
As a rule:
Choose a UPS with 25–30% higher capacity than your current total load.