Home » Product » Low Voltage Transformers » Single Phase Transformer » BK industrial control power transformer 440v to 220v 0.1kva-5kva

BK industrial control power transformer 440v to 220v 0.1kva-5kva

Model Number: BK-50VA
Power: 100VA-5KVA
Frequency: 50Hz/60Hz
Standard: IEC-204-1 JB5555 GB5226…
Input Voltage: 380VAC / 220VAC
Output voltage: AC220V/110V/48V/35V/24V/12V
Type: Dry-type
Power Transformer price: Competitive and Reasonable
Phase: Single
Coil Number: AUTOTRANSFORMER
Usage:Mechanical Equipments
Coil Structure:EI
Place of Origin: Zhejiang, China
Brand Name: ZHENGXI

$89.00

Product Features

High quality iron core
The core is made of high-quality siliconsteel sheet, rules and close, anti-oxidation.high strength.

Mode of connection
The input terminal 0 is a common terminal, and combine into different input voltages with other numbers
The output terminal 11 is a common terminal and combine into different output voltages with other numbers

Model Meaning

Model BK □
B transformer
K control
rated capacity

Technical Parameters

Model NO. BK
Capacity 100VA   150VA   200VA      250VA     300VA     400VA      500VA      700VA   800VA   1KVA   1.2KVA   1.5KVA   2KVA   2.5KVA     3KVA   4KVA   5KVA
Input voltage Two phase 440V/415V/380V/360V
Output voltage Customizable two-phase 440V/12V/24V/36V/48V/60V/120V/220V
Frequency 50Hz/60Hz
Work efficiency ≥98%
Insulation resistance ≥50MΩ
Waveform distortion No additional waveform distortion
Overload capacity Two times the rated current for one minute
Electrical strength Industrial frequency sinusoidal voltage 3000V for onr minute without breakdown phenomenon
Ambient temperature -15°C~+ 40°C

Specifications

MODEL Overall size(mm) Installation size Aperture(K*J)
B D E A C
BK-100VA 98 85 108 84 65 5*8
BK-150VA 105 86 110 76 77 5*8
BK-200VA 105 105 115 85 87 8*11
BK-250VA 105 115 110 85 95 8*11
BK-300VA 115 110 115 90 90 8*11
BK-400VA 135 125 140 110 97 8*13
BK-500VA 135 130 140 110 103 8*13
BK-600VA 152 110 150 120 90 8*13
BK-700VA 152 110 150 120 90 8*13
BK-800VA 152 125 150 120 105 8*13
BK-1KVA 152 142 165 120 120 8*13
BK-1.5KVA 175 170 195 130 120 8.5*17
BK-2KVA 205 215 230 170 130 8*11
BK-2.5KVA 205 225 230 170 140 8*11
BK-3KVA 205 240 230 170 150 8*11
BK-4KVA 235 265 260 195 175 8*11
BK-5KVA 235 280 260 195 190 8*11

Control transformer dimensions

Control transformer dimensions

Working requirements:

  1. Ambient air temperature: -5°C to +40°C, with the highest monthly average temperature not exceeding +30°C;
  2. Installation altitude should not exceed 1000 meters;
  3. When the ambient temperature is +40°C, relative humidity should not exceed 50%, with higher humidity allowed at lower temperatures. The maximum average humidity in the dampest month can reach 90%, with the lowest average temperature of that month being +25°C. Condensation on the product surface due to temperature changes should be considered.

Details

Pure copper high temperature coil
Pure copper high temperature coil
High quality electromagnetic performance silicon steel sheet
High quality electromagnetic performance silicon steel sheet
Security Flip Cover Wiring Protection
Security Flip Cover Wiring Protection
en_USEN
Scroll to Top