Main features
High-intelligent LCD screen
Customers can set soft start values such as current, voltage and power through easy button keys and menu windows with smooth interfaces and easy-to-understand operations.
Input and output ports
With a red copper chrome-plated appearance, it’s of high electrical conductivity and it’s highly reliable and safe to employ.
18 sets of terminal blocks
Rich input and output interfaces, detailed markings, meet different application requirements, simple and convenient operation.
Multi-hole axial fan
Strict wind pressure and hole design to dissipate heat greatly improve the efficiency of heat dissipation and the soft starter’s normal operating condition.
Application-programmable protection function
Provides overall protection functions, like input phase loss, output phase loss, overheating of the soft starter, phase sequence protection, overoperation, starting overcurrent, etc., for ensuring the safety of the equipment.
Flexibility in wire options
Supports 380/220V ±15% input voltage range, 0-400Hz frequency range, can meet the control demands of different industrial motors.
Flexible input and output design
Provides 7 digital input terminals, supports ON/OFF input, 1 terminal supports high-speed pulse input; 2 relay output terminals; 2 analog output terminals (optional 0/4-20mA or 0-10V).
Product standard specifications
| Table1 main technical specifications | |||
| Input | Rated voltage, frequency | 3P AC380V;50/60Hz 2P AC220V;50/60Hz | |
| Voltage Range | 3P AC360V~450V 2P AC190V~250V | ||
| output | Voltage | 0~460V 0~260V | |
| Frequency | Low Frequency :0~300Hz High frequency :0~3000Hz | ||
| Overload Capacity | G Type:110% 150% 1min 200% 4s | ||
| P Type:105% 120% 1min 150% 1s | |||
| Mode of control | V/F control 、High Level V/F control 、V/F Separation control 、No PG current vector control | ||
| Control characteristics | Frequency resolution | Analog Setting | Max output frequency 0.1% |
| Digital Setting | 0.01Hz | ||
| Frequency accuracy | Analog input | Within the max output frequency 0.2% | |
| Digital input | Within the setting output frequency 0.01% | ||
| V/F Curve | |||
| V/F Control | Moment Improvement | Manually set :Rated output 0.0~30.0% Auto Improvement:According output current and motor parameters to auto improve moment. | |
| Automatic flow limiting and voltage limiting | Whether in the process of acceleration, deceleration or stable operation, the stator current and voltage of the motor can be automatically detected, and it can be suppressed to the allowed range according to a unique algorithm to minimize the possibility of system failure jumping. | ||
| Inductive vector control | voltage frequency characteristics | Automatically adjust the output voltage-frequency ratio according to the motor parameters and unique algorithms. | |
| Torque characteristics | Starting torque:3.0 Hz 150% rated torque (VF control)150% rated torque at 1.0 Hz (Advanced VF Control)150% rated torque at 0.5 Hz (no PG current vectorcontrol)Constant operating speed accuracy :≤0 2% ratedsynchronous speedVelocity fuctuation :s+0.5% rated synchronous speedTorque response :≤20 ms (no PG current vectorcontrol) | ||
| Self-determination of motor parameters | Without any restrictions, automatic parameter detection can be completed under the static and dynamic motor to obtain the best control effect. | ||
| Current and voltage suppression |
The whole process of current closed-loop control andcomplete avoidance of current impact has a perfectover-current over-voltage suppression function | ||
| Under voltage suppression in |
Especially for users with low grid voltage and frequent grid voltage fuctuations, even if it is below the allowed voltage range, the system |
||
| operation | can maintain the maximum possible running time based on unique algorithms and residual energy allocation strategies. | |||
|
Typical function |
Multi-Speed running
PID control RS485 |
16-stage programmable multi- speed control and multiple running modes are optional. Pendulum frequency operation: preset frequency, center frequency adjustable, state memory and recovery after power
outage Built-in PID controller (preset frequency) . Standard configuration RS485 communication function, multiple communication protocols are optional, and there is linkage synchronization control function. |
||
| Frequency setting | Analog input | DC Voltage 0~10V,DC Current 0~20mA | ||
| Digital input | Operation panel setting, RS485 interface setting, UP/DW terminal control, and various combination settings with analog input can also be made. | |||
|
Output signal |
Digital output | Two DO terminals open collector output and two programmable relay outputs (TA,TB,TC), up to 61 meaning choices | ||
| Analog output | T~wo analog s~ignals output, the output range of
achieve the set frequency, output frequency and other physical output |
|||
| Automatic Steady
Pressure Operation |
According to the need, dynamic, static and non-stable can be selected to obtain the most stable operation effect | |||
| Acceleration and
deceleration Time setting |
0.1 s~3600.0 min continuous adjustable, S type , straight-line optional |
|||
| B r e a k i n g | Energy Brake | The starting voltage, the return voltage and the energy consumption braking rate are continuously adjusted | ||
| DC Brake | Stop DC brake s~tart frequency :0.00~[ F00.13]~upper limit frequency | |||
| Magnetic flux Brake |
0~100 0 :Be of no effect |
|||
| Low Noise Operation | Carrier frequency 1.0KHz~ 16.0KHz continuously adjustable to minimize motor noise | |||
| Speed tracking speed Restart function | It can realize the function of smooth restart and instant stop restart of motor in operation | |||
| Counter | One internal counter to facilitate system integration | |||
| Function | Frequency setting of upper and lower limits, frequency hopping operation, reversal operation limit, slip frequency compensation, RS485 communication, frequency increment, deceleration control, fault self-recovery operation, etc | |||
| Operation panel
display |
Running State | Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback, analog input and output, etc |
| Alarm
Content |
The last six fault records, the last fault trip when the output frequency, set frequency, output current, output voltage, DC voltage, module
temperature and other 6 operating parameters record |
|
| Defective function | Over-current, over-voltage, under-voltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase
deficiency, abnormal tuning of motor parameters, internal memory failure, etc |
|
|
ENVIRON MENT |
Ambient
temperature |
-10℃~+40℃ |
| Ambient humidity
Ambient environment |
5%~95%RH ,No condensation
Indoor (no direct sunlight, no corrosion, flammable gas, no oil mist, dust, etc) |
|
| Altitude | 10% for each 1000 m increase | |
| ORGANAZ ATION | levels of
protection |
IP20 |
| cooling-down method | Air cooling with fan control | |
| Installation way | Wall mounted, cabinet type | |
Wiring instructions
Control mode: V/F control, sensorless vector control (SVC)
Overload capacity: 150% rated current for 60 seconds, 180% rated current for 10 seconds
Source of frequency reference: keyboard, analog input, HDL, serial communication
Function of PID control: supports simple PLC and multi-level speed adjusting function, the speed level can be as much as 16
Range of frequency: 0-400Hz
Benefits
Excellent efficiency and energy saving: By accurately controlling the motor’s start and stop process, energy loss of the motor is saved and system efficiency is improved.
Easy to install and operate: compact size takes up less space, easy adjustment of operation panel, quick debugging, saving time and money on installation.
Intelligent protection system: integrated with several protection functions to prevent motor and drive equipment failure and ensure long-term reliable operation.
Control flexibility: provide a variety of control modes to satisfy different demands of loads and switch between several working modes easily.
Application fields
Industrial automation: suitable for motor drives of various kinds of mechanical devices, such as conveyors, pumps, fans, etc.
Manufacturing: being used heavily in several production lines and automatic control systems for increasing productivity.
Water treatment system: being used in water pump control and flow regulation for a smooth system operation.
Building equipment: usable for building elevator motor control, air conditioners, and other building equipment.
Why use this drive frequency inverter?
Smart control: advanced V/F control technology and SVC sensorless vector control make the motor starting process smooth and efficient, and extend the service life of equipment.
Universal protection: multiple protection mechanisms ensure the stable operation of motors and drives in any environment, thereby reducing the cost of maintenance.
Easy to operate: LCD display and easy button control make debugging and operation more convenient and intuitive.
Energy-saving and high efficiency: precise speed control is achieved through smart control to prevent energy waste.
Choosing this drive frequency inverter, you will experience more precise control, more stable operation and longer equipment life.









