Stable & Efficient Power Conversion
Single to 3-Phase Conversion: 220V single-phase to 380V three-phase output for industrial applications.
Easy Operation: Simple and easy-to-use interface for easy setup and adjustment.
Advanced Control: V/F control, vector control, and PID control supported for best performance.
Customizable & Durable: Different power ranges (4KW-160KW) available with customization options.
Product standard specifications
| Table1 main technical specifications | |||
| Input | Rated voltage, frequency | 3P AC380V;50/60Hz 2P AC220V;50/60Hz | |
| Voltage Range | 3P AC360V~450V 2P AC190V~250V | ||
| output | Voltage | 0~460V 0~260V | |
| Frequency | Low Frequency :0~300Hz High frequency :0~3000Hz | ||
| Overload Capacity | G Type:110% 150% 1min 200% 4s | ||
| P Type:105% 120% 1min 150% 1s | |||
| Mode of control | V/F control 、High Level V/F control 、V/F Separation control 、No PG current vector control | ||
| Control characteristics | Frequency resolution | Analog Setting | Max output frequency 0.1% |
| Digital Setting | 0.01Hz | ||
| Frequency accuracy | Analog input | Within the max output frequency 0.2% | |
| Digital input | Within the setting output frequency 0.01% | ||
| V/F Curve | |||
| V/F Control | Moment Improvement | Manually set :Rated output 0.0~30.0% Auto Improvement:According output current and motor parameters to auto improve moment. | |
| Automatic flow limiting and voltage limiting | Whether in the process of acceleration, deceleration or stable operation, the stator current and voltage of the motor can be automatically detected, and it can be suppressed to the allowed range according to a unique algorithm to minimize the possibility of system failure jumping. | ||
| Inductive vector control | voltage frequency characteristics | Automatically adjust the output voltage-frequency ratio according to the motor parameters and unique algorithms. | |
| Torque characteristics | Starting torque:3.0 Hz 150% rated torque (VF control)150% rated torque at 1.0 Hz (Advanced VF Control)150% rated torque at 0.5 Hz (no PG current vectorcontrol)Constant operating speed accuracy :≤0 2% ratedsynchronous speedVelocity fuctuation :s+0.5% rated synchronous speedTorque response :≤20 ms (no PG current vectorcontrol) | ||
| Self-determination of motor parameters | Without any restrictions, automatic parameter detection can be completed under the static and dynamic motor to obtain the best control effect. | ||
| Current and voltage suppression |
The whole process of current closed-loop control andcomplete avoidance of current impact has a perfectover-current over-voltage suppression function | ||
| Under voltage suppression in |
Especially for users with low grid voltage and frequent grid voltage fuctuations, even if it is below the allowed voltage range, the system |
||
| operation | can maintain the maximum possible running time based on unique algorithms and residual energy allocation strategies. | |||
|
Typical function |
Multi-Speed running
PID control RS485 |
16-stage programmable multi- speed control and multiple running modes are optional. Pendulum frequency operation: preset frequency, center frequency adjustable, state memory and recovery after power
outage Built-in PID controller (preset frequency) . Standard configuration RS485 communication function, multiple communication protocols are optional, and there is linkage synchronization control function. |
||
| Frequency setting | Analog input | DC Voltage 0~10V,DC Current 0~20mA | ||
| Digital input | Operation panel setting, RS485 interface setting, UP/DW terminal control, and various combination settings with analog input can also be made. | |||
|
Output signal |
Digital output | Two DO terminals open collector output and two programmable relay outputs (TA,TB,TC), up to 61 meaning choices | ||
| Analog output | T~wo analog s~ignals output, the output range of
achieve the set frequency, output frequency and other physical output |
|||
| Automatic Steady
Pressure Operation |
According to the need, dynamic, static and non-stable can be selected to obtain the most stable operation effect | |||
| Acceleration and
deceleration Time setting |
0.1 s~3600.0 min continuous adjustable, S type , straight-line optional |
|||
| B r e a k i n g | Energy Brake | The starting voltage, the return voltage and the energy consumption braking rate are continuously adjusted | ||
| DC Brake | Stop DC brake s~tart frequency :0.00~[ F00.13]~upper limit frequency | |||
| Magnetic flux Brake |
0~100 0 :Be of no effect |
|||
| Low Noise Operation | Carrier frequency 1.0KHz~ 16.0KHz continuously adjustable to minimize motor noise | |||
| Speed tracking speed Restart function | It can realize the function of smooth restart and instant stop restart of motor in operation | |||
| Counter | One internal counter to facilitate system integration | |||
| Function | Frequency setting of upper and lower limits, frequency hopping operation, reversal operation limit, slip frequency compensation, RS485 communication, frequency increment, deceleration control, fault self-recovery operation, etc | |||
| Operation panel
display |
Running State | Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback, analog input and output, etc |
| Alarm
Content |
The last six fault records, the last fault trip when the output frequency, set frequency, output current, output voltage, DC voltage, module
temperature and other 6 operating parameters record |
|
| Defective function | Over-current, over-voltage, under-voltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase
deficiency, abnormal tuning of motor parameters, internal memory failure, etc |
|
|
ENVIRON MENT |
Ambient
temperature |
-10℃~+40℃ |
| Ambient humidity
Ambient environment |
5%~95%RH ,No condensation
Indoor (no direct sunlight, no corrosion, flammable gas, no oil mist, dust, etc) |
|
| Altitude | 10% for each 1000 m increase | |
| ORGANAZ ATION | levels of
protection |
IP20 |
| cooling-down method | Air cooling with fan control | |
| Installation way | Wall mounted, cabinet type | |

Tip: Install an anti-interference filter to prevent signal interruption. Never use ca
pacitors or surge suppressors in the output end.