Technical Parameters
|
Specification
|
DNB-0.5KVA up to 30KVA
|
|
Input Voltage
|
80-260V AC or customized
|
|
Output Voltage
|
220V AC or customized
|
|
Output Precision
|
±10%(Adjustable)
|
|
Frequency
|
50/60Hz
|
|
Power Factor
|
80%
|
|
Efficiency
|
>95%
|
|
Control Type
|
Relay Type
|
|
Operating Temperature
|
-10℃~+40℃
|
|
Over/Low Volt Protection
|
YES
|
|
Circuit Protection
|
YES
|
|
Digital Display
|
Show input and output voltage
|
| Model | DNB-500VA | DNB-1000VA | DNB-1500VA | DNB-2000VA | DNB-3000VA | |
| DNB-5000VA | DNB-10KVA | DNB-15KVA | DNB-20KVA | DNB-30KVA | ||
| Phase | Single phase | |||||
| Input voltage | AC 100-260V or customized | |||||
| Output voltage | AC 220V or customized | |||||
| Frequency | 50Hz/60Hz | |||||
| Precision | ±10% | |||||
| Efficiency | >95% | |||||
| Control type | Relay type | |||||
| Digital display | Show input and output voltage | |||||
| Protection | Over/Under Voltage, Over Load, Short Circuit, Over Temperature | |||||
| Ambient temperature | -10°C~+ 40°C | |||||
| Relative Humidity | <95% | |||||
| Waveform Distortion | No additional wave form distortion | |||||
| Insulating Resistance | Normally more than 2MΩ | |||||
| Insulating Class | Class B | |||||
|
Protection |
Over Voltage | Output Voltage ≥ 245V ± 4V | ||||
| Low Voltage | Output Voltage ≤ 180V ± 4V | |||||
| Over Loading | More than 120% | |||||
| Over Temperature | 120℃±10℃ | |||||
| Delay Time | Longtime(180 second) / short time(6 second) | |||||
| Power | 500VA | 1000VA | 1500VA | 2000VA | 3000VA | |
| Packing Size(cm) | 15.3*7.6*23.4 | 15.3*7.6*23.4 | 15.3*7.6*23.4 | 16.2*90*24.8 | 18.2*13.4*28.5 | |
| G.W(Kgs) | 2.1 | 2.4 | 2.98 | 3.98 | 6.73 | |
| Power | 5000VA | 10KVA | 15KVA | 20KVA | 30KVA | |
| Packing Size(cm) | 15.3*7.6*23.4 | 33*19.6*37.6 | 30.2*29.4*38.8 | 30.2*29.4*45.8 | 34.9*34.4*50.8 | |
| G.W(Kgs) | 10 | 16.93 | 21.62 | 27.65 | 33.63 | |
| The size and weight vary depending on the voltage range, and are subject to the customized actual product. | ||||||